Blowers
Industrial blowers from Secomak (UK) and tangential fans from LTG (Germany), supplied, sized, and serviced by Hurll Nu-Way. Choose a belt-driven high velocity blower for pressure up to 186 mbar, a direct drive blower for no-maintenance airflow up to 2,100 m³/h, a side channel blower for bigger lifts or vacuum, or a tangential fan for an even curtain of air across a machine.
Which blower do you need?
Start with the pressure your process needs, then the flow. Figures are peak flow and peak pressure from each model's curve.
High velocity (belt drive)
- 575/1300 m³/h · 41 mbar
- 575/1-3300 m³/h · 41 mbar
- 575/3390 m³/h · 28 mbar
- 575/4250 m³/h · 52 mbar
- 428/A636 m³/h · 77 mbar
- 428/D600 m³/h · 69 mbar
- 428/F350 m³/h · 98 mbar
- 428/G500 m³/h · 98 mbar
- 451/1680 m³/h · 116 mbar
- 451/2953 m³/h · 126 mbar
- 580/1700 m³/h · 74 mbar
- 580/2920 m³/h · 48 mbar
- 492/1980 m³/h · 99 mbar
- 492/2710 m³/h · 135 mbar
- 492/3900 m³/h · 120 mbar
- 587/1850 m³/h · 58 mbar
- 587/2760 m³/h · 98 mbar
- 587 Turbo/111 · 186 mbar
- 587 Turbo/151 · 186 mbar
Direct drive (no maintenance)
Side channel and tangential
- Side Channel BlowersUp to 2,400 m³/h
- LTG Tangential Fans 25 to 90 mm25 to 90 mm
- LTG Tangential Fans 125 to 200 mm125 to 200 mm
- LTG VQ Tangential Fans200 to 1,000 mm
Not sure which fits? Ask our engineers or call 1300 556 380 and we will size it for you.
Which type of blower?
High velocity
Belt-driven centrifugal blowers giving 28 to 186 mbar. Best for air knives, blow-off, drying, and process air where pressure matters. 0.55 kW to 15 kW.
Direct drive
Impeller straight on the motor shaft, so no belts and no bearing assembly to maintain. Lower pressure (5 to 33 mbar at 50 Hz) with flows up to 2,100 m³/h. Ideal for burners and air process heaters.
Side channel
Regenerative blowers for pressure or vacuum from 500 to 1,750 mbar abs, up to 2,400 m³/h, with ATEX versions.
Tangential (LTG)
Long impellers that give a wide, even air curtain across a machine, from 25 mm to 1,000 mm diameter and up to 500°C.
Australia runs on 50 Hz, so all direct drive figures here are 50 Hz. Secomak's /60 models are the same blowers rated at 60 Hz.
Overhaul, service, and related products
Blower overhaul
Bearings, belts, impellers, and motors replaced and the blower tested, on site or in our workshop.
Book a blower overhaulSecomak gas boosters
Secomak also makes gas boosters that raise gas supply pressure for burners and boilers.
See gas boostersBlower FAQs
What is the difference between a high velocity and a direct drive blower?
A high velocity blower uses a belt drive to spin its impeller faster, giving much higher pressure (up to 186 mbar). A direct drive blower mounts the impeller on the motor shaft, so there is no belt or bearing assembly to maintain, but pressure is lower.
What do peak flow and peak pressure mean?
They are the two ends of a blower's performance curve. Peak pressure is reached at low flow, and peak flow at lower pressure. The datasheet curve shows the flow you get at your working pressure.
Why are there 50 Hz and 60 Hz figures?
A blower spins faster on a 60 Hz supply, so it moves more air at more pressure. Australia and New Zealand use 50 Hz, so the 50 Hz figures apply here.
Do you overhaul blowers?
Yes. Our technicians overhaul Secomak and other industrial blowers, replacing bearings, belts, and impellers, on site or in our Glen Waverley workshop.
How do I choose the right blower?
Tell us the flow, the pressure, the air temperature, and your power supply. Our engineers will size the blower against its curve and recommend the model.
Page last updated October 2026.
Need a blower sized for your process?
Tell us the flow, the pressure, the air temperature, and your power supply, and our engineers will recommend the right blower.