Nu-Way Multiplex MP Gas, Oil and Dual Fuel Burner
Industrial process burners with exceptional flame stability over a wide turndown, from low gas and air pressures. For furnaces, kilns, and process heat.
At a glance: The Nu-Way Multiplex MP is an industrial process burner for gas, light oil, or dual fuel, with nominal ratings from 60 kW (MP2) to 11,700 kW (MP400). It gives exceptional flame stability with up to 30:1 turndown on gas, from low gas and air pressures, and suits furnaces, kilns, ovens, and incinerators. Hurll Nu-Way supplies, commissions, and services Nu-Way Multiplex burners in Australia.
Stable flame across a wide turndown
The Multiplex is designed to stay highly stable over a wide turndown, from relatively low gas and air pressures. Gas and air can be controlled by a gas proportionator and air butterfly valves, or by a mechanical or electronic ratio control system for maximum turndown.
For high excess air firing, the air valve stays fully open and the gas valve alone controls output, which keeps the volume of combustion products in the furnace fairly constant across the range. The basic burner can be supplied without a tunnel and fire through a hole in the furnace wall.
It runs on all commercial gases, light oil, or dual fuel. Tunnels come in stainless steel (to 450°C), heat resistant steel (to 900°C), silicon carbide (to 1,300°C), or refractory quarls (to 1,450°C), in low, medium, or high velocity, with extended projections available. Nu-Way is based in Droitwich Spa, England, and is part of the Enertech group alongside Bentone.
Key advantages
- Exceptional flame stability
- Up to 30:1 turndown on gas
- Low air and gas pressure requirements
- Low, medium, and high velocity options
- Metal, silicon carbide, or refractory tunnels
- Inner assembly easily removed
Nu-Way Multiplex MP specifications
- Nominal rating 60 to 11,700 kW at 10 mbar gas and air
- Over-firing Up to 50% with higher gas and air pressures
- Fuels All commercial gases, light oil, or dual fuel
- Turndown Up to 30:1 on gas
- Tunnel temperatures 450°C to 1,450°C depending on material
- Velocity Low, medium, or high
- Rating basis Gross CV, balanced chamber
Models and variants
| Gas model | Oil model | Nominal rating (kW) |
|---|---|---|
| MP2 | Not available | 60 |
| MP4 | Not available | 120 |
| MP6 | Not available | 175 |
| MP10 | Not available | 295 |
| MP15 | MPO 15 | 440 |
| MP25 | MPO 25 | 730 |
| MP40 | MPO 40 | 1,170 |
| MP60 | MPO 60 | 1,750 |
| MP100 | MPO 100 | 2,950 |
| MP150 | MPO 150 | 4,400 |
| MP250 | MPO 250 | 7,300 |
| MP400 | MPO 400 | 11,700 |
Nominal ratings at 10 mbar gas and air pressure at the burner inlet. Ask Nu-Way for over-firing above nominal.
Nu-Way Multiplex MP datasheet
The current Nu-Way Multiplex MP datasheet, with ratings, tunnel options, and dimensions.
MP 1 datasheet
Spare parts and service
Burner spare parts
Spare parts for the Nu-Way Multiplex MP, sourced through the manufacturer. Ask us for part numbers and lead times.
Shop burner sparesCommissioning and burner service
Our technicians handle commissioning and ongoing burner servicing, so your Nu-Way Multiplex MP keeps running at its best.
Book a burner serviceNu-Way Multiplex MP FAQs
What output does the Nu-Way Multiplex MP cover?
Twelve sizes with nominal ratings from 60 kW (MP2) to 11,700 kW (MP400), at 10 mbar gas and air pressure. Higher pressures allow over-firing of up to 50%.
Is the MP available for oil and dual fuel?
Yes, from the MP15 (MPO 15) upwards. The MP2 to MP10 are gas only.
What turndown does the Multiplex give?
Up to 30:1 on gas, using a mechanical or electronic ratio control system for maximum turndown.
What combustion tunnels are available?
Stainless steel to 450°C, heat resistant steel to 900°C, silicon carbide to 1,300°C, and refractory quarls to 1,450°C.
Who supplies and services Nu-Way Multiplex MP burners in Australia?
Hurll Nu-Way, based in Glen Waverley, Victoria, supplies Nu-Way Multiplex MP burners and provides commissioning, burner servicing, and spare parts. Call 1300 556 380. In New Zealand, contact Nu-Way Energy on 0800 689 296.
Page last updated October 2026.
Not sure which Nu-Way Multiplex MP model you need?
Tell us about your boiler or process and our engineers will size it for you.