Bentone BG300 to BG950 Gas Burners
Bentone's top range of gas burners for industrial processes and heating larger commercial buildings. Low fuel consumption, high efficiency, and Low NOx versions used around the world.
At a glance: The Bentone BG300 to BG950 is a family of eight industrial gas burners covering 56 to 3,200 kW. They run on natural gas, LPG, or biogas, come in two stage and modulating versions with Low NOx and Siemens LMV37 options, and are fitted with Siemens controls and DUNGS gas trains. They suit industrial boilers, process heating, and larger commercial buildings. Hurll Nu-Way supplies, commissions, services, and stocks spare parts for the BG range in Australia.
Bentone's top range, built for tough environments
The BG300 to BG950 family is Bentone's top range of burners, well designed and robust, for industrial processes and heating of semi-large commercial buildings. These burners have long been the backbone of Bentone and have been constantly modernised to meet new regulations and lower NOx levels.
Units come as standard with quality components, including Siemens controls and DUNGS gas trains. You will find the larger burners operating on boilers worldwide for years, designed and manufactured for tough environments.
Low fuel consumption combined with high efficiency reduces carbon emissions. Versions are available for natural gas, LPG, and biogas, with LMV37 control, Low NOx (LN), modulating (M), and two stage (-2) options.
Key advantages
- Energy saving with low fuel consumption
- Compatible with environmental requirements
- Low NOx versions available
- Available for natural gas, LPG, and biogas
- Available with Siemens LMV37
- Available according to Annex J/K
- Designed for easy maintenance
- Compliant with Australian Standards and Gas Regulations
Bentone BG300 to BG950 specifications
- Output 56 to 3,200 kW
- Models BG300, BG400, BG450, BG550, BG650, BG700, BG800, BG950
- Fuel Natural gas, LPG, biogas
- Controls Siemens LME11, LME22, LMV
- Gas train DUNGS
- Operation Two stage (-2) and modulating (M)
- Options Low NOx (LN), LMV37, Annex J/K, 60 Hz
- Compliance Australian Standards and Gas Regulations
Models in the BG300 to BG950
| Model | Manuals |
|---|---|
| Bentone BG300 | 10 manuals |
| Bentone BG400 | 13 manuals |
| Bentone BG450 | 8 manuals |
| Bentone BG550 | 6 manuals |
| Bentone BG650 | 6 manuals |
| Bentone BG700 | 4 manuals |
| Bentone BG800 | 3 manuals |
| Bentone BG950 | 1 manuals |
Need output and oil flow figures for a specific model? Ask our engineers or call 1300 556 380.
Bentone BG300 to BG950 user manuals and downloads
51 user manuals, grouped by model.
Bentone BG300 10 manuals
- Bentone BG 300-2 LME22 405-412 user manual PDF
- Bentone BG 300 LME11 405-412 user manual PDF
- Bentone BG 300 M 1F 230V (407) user manual PDF
- Bentone BG 300 LME11 407 50/60Hz user manual PDF
- Bentone BG 300 LME11 512 VP UV Biogas user manual PDF
- Bentone BG 300-2 LME22 512 VP UV Biogas user manual PDF
- Bentone BG 300 M LME22 407 RT user manual PDF
- Bentone BG 300-2 LME22 407 50/60Hz user manual PDF
- Bentone BG 300 M LME22 407 50/60Hz user manual PDF
- Bentone BG 300 M BPS2 MB-VEF 407-412 J/K IP40 VPS user manual PDF
Bentone BG400 13 manuals
- Bentone BG 400 LME11 405-412 user manual PDF
- Bentone BG 400-2 LME22 405-412 user manual PDF
- Bentone BG 400 LME11 512 VP UV Biogas user manual PDF
- Bentone BG 400 M LME22 407-412 60Hz user manual PDF
- Bentone BG 400-2 LME22 512 VPS UV 60Hz user manual PDF
- Bentone BG 400 M LME22 407-412 user manual PDF
- Bentone BG 400 M LME22 407-412 RT user manual PDF
- Bentone BG 400-2 LME22 512 VP UV Biogas user manual PDF
- Bentone BG 400 M LME22 407-412 CF user manual PDF
- Bentone BG 400-2 BPS4 ZRDLE 412 B07 user manual PDF
- Bentone BG 400 LME 21. 550 412 B07 user manual PDF
- Bentone BG 400M BPS2 MB-VEF 407-412 VPS J/K IP40 user manual PDF
- Bentone BG 400 LN LME22 412 user manual PDF
Bentone BG450 8 manuals
- Bentone BG 450-2 LME 22 MB-ZRDLE 412-420 user manual PDF
- Bentone BG 450 M LME22 412 user manual PDF
- Bentone BG 450-2 LME22 520 VPS Biogas user manual PDF
- Bentone BG 450 M LME22 412 VPS user manual PDF
- Bentone BG 450 M LME22 412 RT user manual PDF
- Bentone BG 450 M LN LME22 412 user manual PDF
- Bentone BG 450i M LMV 412-412 J/K IP54 user manual PDF
- Bentone BG 450-2 LME 22 MB-ZRDLE 407 user manual PDF
Bentone BG550 6 manuals
Bentone BG650 6 manuals
Bentone BG700 4 manuals
Bentone BG800 3 manuals
Bentone BG950 1 manual
Spare parts and service
Burner spare parts
Genuine spare parts for the Bentone BG300 to BG950, ready to order online.
Shop burner sparesCommissioning and burner service
Our technicians handle commissioning and ongoing burner servicing, so your Bentone BG300 to BG950 keeps running at its best.
Book a burner serviceBentone BG300 to BG950 FAQs
What output range do the Bentone BG300 to BG950 burners cover?
The range covers 56 to 3,200 kW across eight models: BG300, BG400, BG450, BG550, BG650, BG700, BG800, and BG950.
What fuels can the Bentone BG burners use?
BG burners are available for natural gas, LPG, and biogas. Biogas versions have their own user manuals on this page.
Are Low NOx versions available?
Yes. Low NOx (LN) versions are available and widely used, and the range has been continually modernised to lower NOx levels.
What do the M, -2, and i in the model names mean?
M models are modulating, -2 models are two stage, and i models use the Siemens LMV burner management system. Match the manual to the model on your burner's data plate.
Where can I download a Bentone BG user manual?
All 51 BG user manuals are listed on this page, grouped by model from the BG300 to the BG950.
Who supplies and services Bentone BG burners in Australia?
Hurll Nu-Way, based in Glen Waverley, Victoria, supplies Bentone BG burners and provides commissioning, burner servicing, and spare parts. Call 1300 556 380. In New Zealand, contact Nu-Way Energy on 0800 689 296.
Page last updated October 2026.
Not sure which BG300 to BG950 model you need?
Tell us about your boiler or process and our engineers will size it for you.